GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals. GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals.
3.5 stars - "Review for GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals." This GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals. is the best Control I have tried.
LSC Lighting Systems

GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals.

Product ID: GVW12-10T
Brand: LSC Lighting Systems
From: $4,195.00 AUD

View or buy the Control Lighting - GenVI 12ch x 10A Dimmer-TRUpower wallmounted rack. Screw Terminals. from LSC Lighting Systems to discover other options and shipping details.

Description

GVW DESCRIPTION

GenVI 12ch x 10A Dimmer/TRUpower wallmounted rack with individual RCD/MCB per channel.  Screw terminals for power and load connections.

 

Equally at home in the lighting, sound and video markets, the GVW uses TruPower allowing configuration of any of its outputs (in any combination) to be an 8-bit or 16-bit dimmer or a direct power relay channel. This enables the GVW to dim traditional lamps or power moving lights, LED fixtures, video screens or audio power amplifiers – in fact any situation where controlled power distribution or dimming is required.

The colour touchscreen offers the ability to set each channel individually, control the outputs locally and view any external fault conditions that may be present.

As well as having local and DMX control, the GVW is also RDM (Remote Device Management) enabled, allowing the user to change the DMX address of the unit and view any fault conditions including over-temperature and loss of phase or DMX signal from any RDM controller.

Each circuit on the GVW is protected by an RCBO, rated at either 10A or 25A. Optional Neutral Disconnect MCBs can be provided where RCBOs are not desirable.

The GVW offers a sophisticated rigger's control that can replay scenes or chases, each of which can be individually programmed in addition to a 'DMX loss' scene that can be activated as an emergency backup on loss of a DMX signal. This emergency backup scene can be programmed via the front-panel controls or via a snapshot of the DMX input signal.

 

FEATURES

  • TruPower dimmer and power distribution
  • RCBO per channel
  • Auto Power Mode – switches Relay channels On when DMX is applied and Off when DMX is no longer present
  • Dimmer channels can be 8 bit or 16 bit
  • RDM – Remote Device Management enabled
  • Operates on mains input voltages between 90V and 260V phase to Neutral
  • On-board Help screens
  • Visual alarms for Phase Fail, over-temperature and loss of DMX
  • PTFD (Pulse Transformer Fired Dimming)
  • Local rigger's control
  • Auto fan control (user defined)
  • Colour touchscreen with simple and intuitive navigation
  • Unistrut hook bracket available for simple mounting

GVW is equally at home in any of the following environments:

  • Dimming conventional, LED, neon lights
  • Powering moving lights
  • Powering LED fixtures
  • Powering video walls
  • Powering audio systems

 

SPECIFICATIONS

GVW Specifications

GVW12/10

GVW6/25

Channels

12

6

Max Load per Channel

10 Amps

25 Amps

Thermal Magnetic Breakers

alt

alt

RCD/GFI Protection

alt

alt

RCD/GFI Current Trip

30mA/Channel

DMX-512A Input with RDM Functionality

alt

alt

Control Surface

3.2" color LCD with touchscreen

Pre-heat (min) and Top Set (max) Levels per Channel

alt

alt

Remote Monitoring and Control via RDM

alt

alt

Auto Power Mode - switches Relay channels On when DMX is applied and Off when DMX is no longer present

alt

alt

Dimmer Channels can be 8 bit or 16 bit

alt

alt

Visual Alarms for Phase Fail, Over-Temperature and Loss of DMX

alt

alt

PTFD (Pulse Transformer Fired Dimming)

alt

alt

Local Rigger's Control

alt

alt

Fan Control

Auto or user programmable speed

Colour Touchscreen with Simple and Intuitive Navigation

alt

alt

Dimming Curves

4

Operating Temperature Range

0-40°C

Output Connector Options

/A

12 x 3-pin 10A Australian outputs

6 paired Australian outputs (20A + 15A per channel)

/T

Hardwired

Power Supply

Nominal 100-240V, 3-phase star with fully rated Neutral, 50-60Hz,

operating range typically 90-260V, 45-65Hz,

earthing system: TN-S

Power Input Connection

An M25 nickel-plated brass cable gland for installing power cable is supplied but not fitted

Control Input

DMX512 (1990) or DMX512-A (E1-11) and RDM (E1-20) via right-hand side panel mounted 5-pin AXR In and Thru connectors

Product Dimensions - W x D x H

490 x 270 x 250mm

19.3 x 11 x 9.8 inches

Shipping Dimensions - W x D x H

 

550  x 340  x 310mm

21.7  x 13.4 x 12.2 inches

Product Weight

21.5kg/47.3 lb

21.5kg/47.3lb

Product Weight (Packed)

25kg/55lb

25kg/55lb

Shipping Weight (Australia)

25kg/55lb

25kg/55lb

Shipping Weight (Export)

25kg/55lb

25kg/55lb

Note: other current ratings (such as 10A) are available on request, indent order only. Minimum order quantities may apply.

ABOUT GENVI GVW

The GVW takes the incredibly popular GenVI dimmer /distro technology and houses it in a compact wallmount chassis for permanent installation into venues.



The GVW is available with either front-mounted GPO outputs (for use with patch bays, such as the LSC REDBACK patch bay series) or with internal screw terminals for hardwired applications. The minimal height of the unit allows four to six GVW wallmount racks to be placed vertically on a wall to achieve a greater density of dimmers than with alternative products.

In conjunction with the REDBACK patch system, up to four GVW racks can be installed each side of the patch bay, allowing for 96 channels of dimming/power distro and patch bay to be installed in an area of only 1.8m high x 1.7m wide. This combination allows the controls to be within a comfortable working height (between 1.8m and 1m), whilst ensuring no cables touch the floor, eliminating Workplace Health and Safety risks often encountered with other systems.



The hardwired variant has the terminals on the rear of the chassis, forming an installation frame that can be attached to a wall. All the supply and load cable terminations can be completed before the main body and electronics are installed. This method ensures easier access when terminating cables, as well as ensuring no accidental damage to the rack's electronics by tradespeople.
 

DOWNLOADS