IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq
4 stars - "Review for IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq" This IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq is the best System Types I have tried.
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 1
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 2
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 3
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 1
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 2
  • IILD500 Professional Rack Mountable Audio Induction Loop Driver 6.4Arms for areas up to 700m sq - Image 3

Description

Ampetronic
IIILD500 Professional Rack Mountable Audio Induction Loop Driver    6.4Arms   for areas up to 700m2


The ILD500 is a professional audio induction loop driver capable of driving loop areas of upto 700m2 with unsurpassed clarity of sound for both music and speech for superior intelligibility.
Based on proven and highly reliable technology it is backed by an unrivalled 5 year warranty and free technical support. Improved power output provides outstanding value without compromise.It boasts all the usual features found on Ampetronic equipment such as metal loss correction and automatic gain Control.
The ILD500 is a compact and elegant unit suitable for freestanding, wall mounting or rack mounting.

Features

  • Area coverage to >700m2
  • Low lifetime cost 
    Excellent proven reliability
    5 year warranty
  • Unparalleled sound quality 
    Excellent intelligibility
    Speech optimised gain control 
    High voltage headroom avoids high frequency clipping
  • Metal loss corrector corrects frequency dependent loss from metal structures
  • Rack mount brackets included
  • Microphone (XLR) and line inputs
  • Extensive input adaptors available for any audio input requirement
  • Free technical support line for advice, design and install
 

Applications include

  • Conference facilities
  • Theatres
  • Sports halls
  • Lecture Halls
  • Cinemas
 

Equipment supplied as standard with the ILD500

  • Handbook and installation instructions
  • 197 x 252mm loop system present sign (deaf logo)
  • Region specific mains cable
  • Loop connector
 

ILD500 optional accessories

Ashton Audiocan supply an extensive range of additional accessories for installation – discuss your requirements with our sales team and we will provide materials and equipment to suit your application.
Input adaptorsA range of input adaptors and interface cables to accept most audio source inputs, see table below
Installation Accessories• 18mm x 0.25mm copper tape
• PVC extrusion to protect copper tape
• Installation / warning tape to fix cable or tape to a floor
Wall mount bracketsWMF1-U
Phase shifterSP5 for an array system requires a design which can be provided by Ampetronic

 

Input adaptors and preamplifiers

By using the appropriate input adaptor or preamplifier the ILD500 will accept multiple additional inputs or audio inputs 
from other sources:
Input typeAdaptor
Additional microphone and / or line inputsMP221 preamps can drive up to 2 mics + 2 line inputs
100V line input
Low impedance speaker line
Line Level
ATT-UJ & ATT-UX transformer isolated attenuators
Unbalanced microphonesMAT1 adaptor

 

Standards compliance

The ILD500 is CE marked to all relevant safety and EMC standards. 
All Ampetronic amplifiers can be used to create a system that meets the requirements of IEC118-4 and the relevant recommendation of BS7594, however the design and installation of the system is equally important to meet these Induction Loop standards. 
 
 

Perimeter Loops – Area Coverage (maximum)

Room aspect ratio1:12:13:1
Maximum area m2420525700
For any Induction Loop System, area coverage is dependent on several factors. Please check these assumptions and contact Ampetronic for advice if required:
  • Loop must be 1-2m above or below the receiver height
  • There should be no metal structures in the plane of the loop
  • Sufficient voltage to drive the loop – check the cable table below
 

Maximum Cable Length

The ILD500 is designed for SINGLE TURN loops for optimum audio quality.
  • Loops with DC resistance from 0.3 to 2.0Ω
  • Impedance up to a maximum of 2.2Ω
Maximum cable length is dependent on cable type and on the application:
Cable typeMaximum Cable Length (m)
 Normal Use*Transient Speech*
1.0mm2 copper8396
2.5mm2 copper114145
4.0mm2 copper118154
1.8mm2 flat copper tape147170
* Short term speech (e.g. service counter, airport PA system) can cope with limited clipping at high frequencies – Ampetronic recommends delivery of full current up to 1.2kHz for these applications. 
Longer term usage or signals with music or high quality audio must deliver full current to at least 1.6kHz to prevent fatigue and give acceptable intelligibility. Many commercially available systems do not deliver sufficient voltage to reproduce critical high frequencies – ask us for more details.
 
 

ILD300 Specifications


INPUTS

Power85W 230V AC nominal, 45-65Hz [120V option available]
Power switch and LED indicator on front panel
Microphone inputXLR balanced microphone input for 200-600Ω microphones;
15dB user selectable gain boost; + 15V DC phantom power (selectable); sensitivity – 70dBu; front panel recessed gain control
Line input6.4mm jack socket balanced line input; sensitivity – 30dBu; overload protected; front panel recessed gain control
Slave I/O6.4mm jack insert point for connection of SP5 phase shifter
0dBu signal can be used for recording

 

OUTPUTS

Drive voltage14.1 Vrms (20.0Vpk) at maximum output current
Drive current• 6.4 Arms (9.0Apk) continuous 1kHz sine wave
• Short term peaks: >13A
• Front panel recessed control
• Drive current indicated on 6-LED display in 2dB increments
Loop connectorNeutrik NL4 (supplied)
Loop MonitorProvides access to actual audio signal in loop
3.5mm stereo headphone connector on front panel

 

AUDIO SYSTEM

Freq. response80Hz to 6.5kHz
DistortionTHD+N
Automatic Gain ControlThe AGC is optimised for speech. Dynamic range >36dB
Front panel recessed input level control
Metal loss correctionCorrects system frequency response due to metal structures in a building. Gain constant at 1kHz, adjustable gain slope from 
0 to 3dB per octave.
This does not compensate for signal loss from metal structures which can be significant.

 

 

ADDITIONAL FUNCTIONS

Fault MonitoringThree LED fault indicators on the front panel;
• Overload – delivering over the rated current
• Overheat – unit is too hot (mutes output signal)
• Loop error – short circuit / open circuit error
AncillaryTo supply Ampetronic ancillary units
±15V DC 0.15A power outlet on rear panel
CoolingForced ventilation. Air intake on left panel, air ejection at rear

 

PHYSICAL

DimesnsionsFull width 1U 19" rack mount.
Width 430mm Depth 220mm Height 44mm
Mounting options• Freestanding
• 1U 19" rack mount (brackets included)
• Wall mounting (requires additional brackets)
Weight3.75kg
EnvironmentIP20 protection; 20 to 90% relative humidity; 0 to 35ºC



Ashton Audio