ILD300 Professional Rack Mountable Audio Induction Loop Driver 4.9Arms for areas up to 420m sq
Description
Ampetronic
ILD300 Professional Rack Mountable Audio Induction Loop Driver 4.9Arms for areas up to 420m2
The ILD300 is a professional audio induction loop driver capable of driving loop areas in excess of 400m2 with an unsurpassed clarity of sound for both music and speech for superior intelligibility.
Based on proven and highly reliable technology it is backed by an unrivalled 5 year warranty and free technical support. Improved power output provides outstanding value without compromise.
It has all the usual high quality features found on Ampetronic equipment such as metal loss correction and speech optimised gain control.
The ILD300 is very compact and elegant, suitable for freestanding, wall mounting or rack mounting.
Features
- Area coverage to >400 m2
- Low lifetime cost
Excellent proven reliability
5 year warranty - Unparalleled sound quality
Excellent intelligibility
Speech optimised gain control
High voltage headroom avoids high frequency clipping - Metal loss corrector corrects frequency dependent loss from metal structures
- Very compact: 215 x 220 x 44 mm
- Microphone (XLR) and line inputs
- Extensive input adaptors available for any audio input requirements
- Free technical support line for advice, design and install
Applications include
- Conference facilities
- Theatres
- Sports halls
- Educational environments
- Places of worship
- Lecture Halls
Equipment supplied as standard with the ILD300
- Handbook and installation instructions
- 197 x 252mm loop system present sign (deaf logo)
- Region specific mains cable
- Loop connector
ILD300 optional accessories
Ashton Audio can supply an extensive range of additional accessories for installation – discuss your requirements with our sales team and we will provide materials and equipment to suit your application.Input adaptors | A range of input adaptors and interface cables to accept most audio source inputs, see table below |
Installation Accessories | • 18mm x 0.25mm copper tape • PVC extrusion to protect copper tape • Installation / warning tape to fix cable or tape to a floor |
Wall mount brackets | WML1-U |
Rack mount brackets | RM-1U |
Phase shifter | SP5 for an array system requires a design which can be provided by Ampetronic |
Input adaptors and preamplifiers
By using the appropriate input adaptor or preamplifier the ILD300 will accept multiple additional inputs or audio inputsfrom other sources:
Input type | Adaptor |
Additional microphone and / or line inputs | MP221 preamps can drive up to 2 mics + 2 line inputs |
100V line input Low impedance speaker line Line Level | ATT-UJ & ATT-UX transformer isolated attenuators |
Unbalanced microphones | MAT1 adaptor |
Standards compliance
All Ampetronic amplifiers can be used to create a system that meets the requirements of IEC118-4 and the relevant recommendation of BS7594, however the design and installation of the system is equally important to meet these Induction Loop standards.
Perimeter Loops – Area Coverage (maximum)
Room aspect ratio | 1:1 | 2:1 | 3:1 |
Maximum area m2 | 250 | 310 | 420 |
- Loop must be 1-2m above or below the receiver height
- There should be no metal structures in the plane of the loop
- Sufficient voltage to drive the loop – check the cable table below
Maximum Cable Length
The ILD300 is designed for SINGLE TURN loops for optimum audio quality.- Loops with DC resistance from 0.2 to 1.2Ω
- Impedance up to a maximum of 1.3Ω
Cable type | Maximum Cable Length (m) | |
Normal Use* | Transient Speech* | |
1.0mm2 copper | 49 | 57 |
2.5mm2 copper | 67 | 85 |
4.0mm2 copper | 70 | 91 |
1.8mm2 flat copper tape | 87 | 101 |
Longer term usage or signals with music or high quality audio must deliver full current to at least 1.6kHz to prevent fatigue and give acceptable intelligibility. Many commercially available systems do not deliver sufficient voltage to reproduce critical high frequencies – ask us for more details.
ILD300 Specifications
INPUTS
Power | 35 W 230 V AC nominal, 45-65 Hz [120 V option available] Power switch and LED indicator on front panel |
Microphone input | XLR balanced microphone input for 200-600 Ω microphones; 15 dB user selectable gain boost; + 15 V DC phantom power (selectable); sensitivity – 70 dBu; front panel recessed gain control |
Line input | 6.4 mm jack socket balanced line input; sensitivity – 30 dBu; overload protected; front panel recessed gain control |
Slave I/O | 6.4 mm jack insert point for connection of SP5 phase shifter 0 dBu signal can be used for recording |
OUTPUTS
Drive voltage | 6.4 Vrms (9.0V peak) at maximum output current |
Drive current | • 4.9 Arms (7.0 Apk) continuous 1 kHz sine wave • Short term peaks >10 A • Front panel recessed control • Drive current indicated on 4-LED display in 3 dB increments |
Loop connector | Wieland ST17/2 (supplied) |
Loop Monitor | Provides access to actual audio signal in loop 3.5 mm stereo headphone connector on front panel |
AUDIO SYSTEM
Freq. response | 80 Hz to 6.5 kHz |
Distortion | THD+N |
Automatic Gain Control | The AGC is optimised for speech. Range >36 dBu Front panel recessed input level control |
Metal loss correction | Corrects system frequency response due to metal structures in a building. Gain constant at 1 kHz, adjustable gain slope from 0 to 3 dB per octave This does not compensate for signal loss from metal structures, which can be significant |
ADDITIONAL FUNCTIONS
Fault Monitoring | Three LED fault indicators on the front panel: • Overload – delivering over the rated current • Overheat – unit is too hot (mutes output signal) • Loop error – short circuit / open circuit error |
Ancillary | To supply Ampetronic ancillary units ±15 V DC 0.15 A power outlet on rear panel |
Cooling | Cooling is by natural convection from product casing |
PHYSICAL
Dimensions | Half width 1U 19" rack mount Width 215 mm Depth 220 mm Height 44 mm |
Mounting options | • Freestanding • 1U 19" rack mount (requires additional rack tray) • Wall mounting (requires additional brackets) |
Weight | 2.25kg |
Environment | IP 20 protection; 20 to 90% relative humidity; 0 to 35 ºC |
Ashton Audio in conjunction with Ampetronic can design your induction loop system for you. Simple induction loop designs are free, complex array systems will be charged for at a nominal rate. You can request a design through our 'Contact Us' Enquiry Form.